72dB Mega Silent Backup Genset 1000kw Emergency Standby Power Generator

Brand Name : Cummins

Model Number : SCF-1100

Certification : ISO, CE, Soncap, EPA

Place of Origin : China

MOQ : 1 set

Price : USD 60000-80000USD

Payment Terms : L/C, T/T, Western Union, MoneyGram

Supply Ability : 20 Sets per Month

Delivery Time : 30 working days

Packaging Details : Plyfilm or plywood

Frequency : 50hz / 60hz

Engine model : KTA38-G5

Starting method : 24V Electric Start

Generator type : Container Type

Noise level dB@7m : 72 dB(A)

Contact Now

SHX 1 Mega Silent Generator Back Up Generator Emergency Standby Power Generator

1. SPECIFICATIONS OF GEN-SET
1.1 Set Model SCF-1100
1.2 Prime at 50HZ, 40℃ ambient 800kW 1000KVA
1.3 Standby at 50HZ, 40℃ ambient 880kW 1100KVA
1.4 Rated Gen-set output 230/400V 50Hz
1.5 Rated Relative humidity ≤ 60 %
1.6 Dimension (L×W×H) 20ft container
1.7 Weight 9050kg
1.8 Fuel consumption 100% prime load 191L/h
1.9 Total heat radiated to ambient 163KW
1.10 Structure of Gen-set The Gen-set adopt integrative structure, engine is fix on high strength steel basic frame, anti vibration instrument between the engine and basic frame, cooling fan have protecting cap, control cabinet and circuit breaker installed on Gen-set.
1.11 Control system (Optional) Basic control panel or Advanced control panel with automatically start-up function and other function.
2. SPECIFICATIONS OF ENGINE
2.1 Engine Brand Cummins
2.2 Engine Model KTA38-G5
2.3 Governor/Class Electrical
2.4 Cylinder NO. 12
2.5 Engine build Vee
2.6 Fuel spray pattern PT direct injection
2.7 start-up method 24V, electric
2.8 Aspiration Turbocharged/Aftercooled
2.9 Cooling mode Radiator cooled (enclose water)
2.10 Bore and stroke 159×159mm
2.11 Compression ratio 13.9:1
2.12 Displacement 38L
2.13 Engine Prime Power at 1500rpm 880KWm
2.14 Engine Standby Power at 1500rpm 970KWm
2.15 Battery capacity 254A/hr
2.16 Starting/Min temperature 7℃
2.17 Lubrication oil capacity 135L
2.18 Coolant capacity - radiator and engine (40℃) 308L
2.19 Exhaust temp - full load prime 499℃
2.20 Exhaust gas flow - full load prime 10663m3/h
2.21 Exhaust gas back pressure max 76mmHg
2.22 Air flow - radiator (40℃ ambient) 15 m 3/s
2.23 Pusher fan head (duct allowance) 40℃ 13mmH 2O
2.24 Air intake - engine - full load prime 4104m3/h
2.25 Standard Air intake temp 25℃
2.26 Fuel type #0 Diesel (Natural temperature)
2.27 Filter system Adopt whole changeable lubricating oil, fuel filter and air filter
2.28 Exhaust system Adopt industrial high efficiency muffler and ripple pipe
3. SPECIFICATIONS OF ALTENATOR
3.1 Alternator Model Stamford/Leroysomer/Farrand
3.2 Alternator Type A.C. Synchronous
3.3 Rated Voltage 230/400V
3.4 Rated Frequency 50HZ
3.5 Rated speed 1500 RPM
3.6 Voltage regulation mode Auto
3.7 Alternator voltage regulation ±0.5%
3.8 Exciting mode Brushless self exciting
3.9 Power factor 0.8 (lagging)
3.10 Phase & wires 3 phase 12 wires
3.11 Rated currency 1443.4A
3.12 Efficiency 0.942
3.13 Insulation class H
3.14 Protection class IP23
3.15 Single load step to NFPA110 100%
3.16 Standards IEC34-1
3.17 Max. Ambient Temperature 40℃
3.18 Min. Ambient Temperature - 20℃
3.19 Max. altitude 1000m
3.20 Weight 2190kg

72dB Mega Silent Backup Genset 1000kw Emergency Standby Power Generator

72dB Mega Silent Backup Genset 1000kw Emergency Standby Power Generator

72dB Mega Silent Backup Genset 1000kw Emergency Standby Power Generator

72dB Mega Silent Backup Genset 1000kw Emergency Standby Power Generator

Our services
  • After-sales:

Once receive any feedback of quality problem we will respond at the first time, and solve the problems within 24 hours.

  • Guarantee:

Warranty period is one year or 1000 hours (depends on which occurs first ). If the failure is caused by turbine manufacturing defects, we will be responsible for problems caused by quality of production or raw material, except the damageable spare parts of genset caused by crew wearing parts, consumable parts for daily use, human error , negligence or failure of following the original maintenance manual provisions, etc.

  • Free training:

We can professionally arrange experienced engineers to provide users with free training in our factory . Certainly , we also provide the paid training of customers’ site.

Company advantages
  • We are a powerful and unity sales team:

we are not just sales, but also professional engineers here to give you fast response of Technical support and power solutions.

90% of our sales team members are with more than 5 years of experience in the generator field.

  • We have professional electrical & mechanical engineers, standby you, to solve the pre/after-sales service.
  • We have strict Inspection dept. to make sure each genset is carefully test before leaving factory.
  • With the experience and knowledge of Gensets, we are enthusiastic and patient, and can communicate with you easily and efficiently.

72dB Mega Silent Backup Genset 1000kw Emergency Standby Power Generator


Product Tags:

Mega Silent Backup Genset 1000kw

      

72dB Silent Backup Genset

      

1000kw Emergency Standby Power Generator

      
Quality 72dB Mega Silent Backup Genset 1000kw Emergency Standby Power Generator for sale

72dB Mega Silent Backup Genset 1000kw Emergency Standby Power Generator Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangdong Sunkings Electric Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)